Hygropalm 1
- Displays % relative humidity, temperature, dew-point, wetbulb
- 100% interchangeable Hygroclip probes
- Wide range of interchangeable probe options to suit every application
- Single point digital probe adjustment
- Hygroflex transmitter interface(display only)
- Technical Data
- Range: 0.....100%rh, -50......+200 deg.C(Probe dependant)
- Diplay: 4 line alphanumeric LCD
- Resolution: 0.1%rh,0.1deg.C, 0.01 calculated values
- range(electronics): 0....99%rh, -10....+60deg.C
- system accuracy at 23deg.C: +/-1.5%rh, +/-0.3K
- Reproducibility: <0.5%rh, 0.1deg.C
- Long Term Stability: 1%rh/year
- Response time: < 15 seconds
- Input Signal: 1(digital)
- housing: ABS 230 x 80 x 30mm
Click Here for Hygropalm Data Sheet
|
|
|
|
 |
Hygrolog
- Autonomous data logger for Hygroclip probes
- Interchangeable proble modules, no calibration
- Precise measurement of %rh and Deg.C
- Robust IP65 ABS housing
- 10,000 value memory
- Validated HW3 software
- Programmable measurement interval 15s to 2 hours
- Logging upto 416 days
- Start/stop memory loop
- User replacemable battery
- Useful range of accessories
- Technical Data
- Range: 0..100% rh; -50..200deg.C(probe dependant), resolution 0.1
- Range(Electronics): -20..+70deg.C with Lithium batteries,
-10..+50deg.C with Alkaline batteries
- System accuracy: +/-1.5%rh, +/-0.3K
- Output Signal: RS232
- Long Term Stability: < 1%rh per year
- Reprducibility: <0.5%rh, <0.1deg.C
- Response time: < 15 seconds
- Memory Capacity(EEPROM): 10,000 values (5000 times %rh % deg.C)
- Housing: IP65, ABS, 230 x 80 x 30mm
Click Here for Hygrolog Data Sheet
|
|
|
|
 |
Hygrolog D
- All the features of Hylgrolog
- Intergrated LC display
- Alarm indicators
- Memory status indicator
- Battery status indicator
- Technical Data
- Range: 0..100% rh; -50..200deg.C(probe dependant), resolution 0.1
- Range(Electronics):-10....+50deg.C
- System accuracy: +/-1.5%rh, +/-0.3K
- Output Signal: RS232
- Long Term Stability: < 1%rh per year
- Reprducibility: <0.5%rh, <0.1deg.C
- Response time: < 15 seconds
- Memory Capacity(EEPROM): 10,000 values (5000 times %rh % deg.C)
- Housing: IP65, ABS, 230 x 80 x 30mm, intergrated LC display
Click Here for Hygrolog D Data Sheet
|
|
|
|
 |
Hygrolog NT
- Integrated or Interchangable Probe
- Integrated Display (optional)
- Alarm Function
- Easy to use by keypad or software
- compliance with requirements for electronic records and signatures 21CFR part II, apendix 11
- Interchangeable complact flash card memory for virtually limitless number of measurement values
- Probe adjustable directly in logger
- Docking station for extended option (Including connection to PC)
- Networkable
Click Here for Hygrolog NT Data Sheet
|
|
|
|

No display/keypad version shown. |
Hygroflex 1
- Industrial transmitter of rhumidity and temperature with digital probe concept
- Wide range of probe configurations
- Reduced service costs thanks to probe interchangeablility
- Calibration on-site is eliminated
- User re-scaleable uptput signals
- Optional siplay with keypad
- Measurement in Ex zones
- Excellent long term stability
- Precise, condensation resistant sensor - Hygromer C94
- Test connection for Hygropalm reference instrument
- Technical Data (including Hygroclip Industrial Probge)
- Probe type: Hygroclip Industrial Series
- Probe inputs: 1 digital or analogue,0..2.5V,10bit A/D, Supply 15VDC,max. 10mA
- Measurement range: 0...100%rh,-50...+200deg.C(probe dependant)
- Range(electronics): 0...100%rh(non condensing)-40...+60deg.C, with display -30...+60deg.C
- Sensors: Hygromer C94(%rh), Pt100 1/3 DIN (temperature)
- Accuracy at 23deg.C: +/-1.5%rh(0...100%rh), +/-0.3K(+/-1%rh, +/-0.2K with special calibration)
- Reproducibility: <0.5%rh/0.1deg.C
- Long term stability: <1%rh/year typical, <0,1K/year
- Adjustment Points: 1 pont(%rh,deg.C) or 4 point (%rh)/ 2 point(deg.C),(only with display/keypad Option)
- Analogue outputs: Factory confirgured to 4...20mA
- Analogue output options: 0...1V, 0...5V,0...10V,0...20mA or 4...20mA(jumper configurable)
- Display/Keypad(option): 3 line LC display, membrane keypad
- Display Resolution: 0.1%rh, 0.1 deg.C
- Housing: IP65 ABS, Dimensions: 207 x 150 x 58mm(metal housing optional)
Click Here for Hygroflex 1 Data Sheet
|
|
|
|

Display/Keypad version shown |
Hygroflex 2
- Industrial transmitter of rhumidity and temperature with digital probe concept
- Wide range of probe configurations
- Reduced service costs thanks to probe interchangeablility
- Calibration on-site is eliminated
- Calculation of different humidoity parameters; dewpoint, mixing, ratio, ect
- Software for adjustment/calibration of probes and instruments configuration
- Optional siplay with keypad
- Measurement in Ex zones
- Excellent long term stability
- Precise, condensation resistant sensor - Hygromer C94
- Test connection for Hygropalm reference instrument
- Technical Data (including Hygroclip Industrial Probge)
- Probe type: Hygroclip Industrial Series
- Probe inputs: 1 digital or analogue,0..2.5V,10bit A/D, Supply 15VDC,max. 10mA
- Measurement range: 0...100%rh,-50...+200deg.C(probe dependant)
- Range(electronics): 0...100%rh(non condensing)-40...+60deg.C, with display -30...+60deg.C
- Sensors: Hygromer C94(%rh), Pt100 1/3 DIN (temperature)
- Accuracy at 23deg.C: +/-1.5%rh(0...100%rh), +/-0.3K(+/-1%rh, +/-0.2K with special calibration)
- Reproducibility: <0.5%rh/0.1deg.C
- Long term stability: <1%rh/year typical, <0,1K/year
- Adjustment Points: 1 pont(%rh,deg.C) or 4 point (%rh)/ 2 point(deg.C),(only with display/keypad option or via PC PS232 interface)
- Digital output: RS232/RS485, software configuration(RS232 Master,RS485 Slave)
- Display/Keypad(option): 3 line LC display, membrane keypad
- Display Resolution: 0.1%rh, 0.1 deg.C
- Housing: IP65 ABS, Dimensions: 207 x 150 x 58mm(metal housing optional)
Click Here for Hygroflex 2 Data Sheet
|
|
|
|

Display/Keypad version shown |
Hygroflex 3
- Industrial transmitter of rhumidity and temperature with digital probe concept
- Wide range of probe configurations
- Reduced service costs thanks to probe interchangeablility
- Calibration on-site is eliminated
- Calculation of different humidoity parameters; dewpoint, mixing, ratio, ect
- Software for adjustment/calibration of probes and instruments configuration
- Optional siplay with keypad
- Measurement in Ex zones
- Excellent long term stability
- Precise, condensation resistant sensor - Hygromer C94
- Test connection for Hygropalm reference instrument
- Technical Data (including Hygroclip Industrial Probge)
- Probe type: Hygroclip Industrial Series
- Probe inputs: 1 digital or analogue,0..2.5V,10bit A/D, Supply 15VDC,max. 10mA
- Measurement range: 0...100%rh,-50...+200deg.C(probe dependant)
- Range(electronics): 0...100%rh(non condensing)-40...+60deg.C, with display -30...+60deg.C
- Sensors: Hygromer C94(%rh), Pt100 1/3 DIN (temperature)
- Accuracy at 23deg.C: +/-1.5%rh(0...100%rh), +/-0.3K
- Reproducibility: <0.5%rh/0.1deg.C
- Long term stability: <1%rh/year typical, <0,1K/year
- Adjustment Points: 1 pont(%rh,deg.C) or 4 point (%rh)/ 2 point(deg.C),(only with display/keypad option or via PC PS232 interface)
- Analogue Outputs: Factory configuraed to 4...20mA
- Analogue output options: 0...1V, 0...5V,0...10V,0...20mA or 4...20mA(jumper configurable)
- Digital output: RS232/RS485, software configuration(RS232 Master,RS485 Slave)
- Display/Keypad(option): 3 line LC display, membrane keypad
- Display Resolution: 0.1%rh, 0.1 deg.C
- Housing: IP65 ABS, Dimensions: 207 x 150 x 58mm(metal housing optional)
Click Here for Hygroflex 3 Data Sheet
|
|
|
|
 |
MP100A/400A
- Precise & stable %rh & Temperature measurement
- Specially designed for outdoor & meteorological measurements
- Condensation resistant sensor
- 0...1 volt output signal(MP100) low power consumption
- Cable length compensation up to 100m on vlotage output versions
- 4...20mA output options (MP400)
- Proven in roadside & airport applications
- Over 30,000 sold
- Technical Data
- Humidity sensor: Hygromer C94
- Temperature Sensor: Pt100/A
- Range: 0...100%rh, -40...+60deg.C
- Accuracy @ 23deg.C: +/-1.5%rh, +/-0.3K
- Long term stability: <1%rh, 0.1K per year typical
- Response time: <15 seconds
- Output signal:
- MP106A:0...1V = 0...100%rh,deg.C 4 wire Pt100 direct
- MP103A:0...1V + 0...100%rh, -40...+60deg.C
- MP408A:4...20mA + 0...100%rh, -40...+60deg.C
- Output load: MP106A/MP103A:min1000Ohm, MP408A: max 500Ohm
- Power Supply: MP106A/MP103A:4.8...30VDC, 3.5mA(3/4wire), 6mA(5wire), MP408A:4.8...30VDC,50mA
- Adjustment: Potentiometer,35,80%rh,Hmin
- Sensor protection: Wire mesh filter
- Mechanical: White delrin probe with IP65 male connector
- MP106A/MP103A 250x25mm(diameter)
- MP408A 260x25mm(diameter)
Click Here for MP100A/400A Data Sheet
|
|
|