Pryde Measurement Pty Ltd - Hach
RETURN TO HOME



sc100 Universal Controller, Standard
  • One Controller for One or Two Sensors
  • One controller for One or Two Parameters
  • One controller for Many Options
  • Plug and Play Operation
  • Simple, Reliable Data Collection

The Model sc100 Controller receives data from one or two sensors. Its plug-and-play, mix-and-match operation lets it fit into any facility or workflow. Digital communication with any Hach digital sensor or probe is simple and reliable.

sc100 is also available with RS485/MODBUS® Communications (LXV401.52.02002) or RS232/MODBUS® Communications (LXV401.52.01002). For other communication options which may be available, contact Hach Technical Support or your Hach representative.

sc100 Universal Controller Data Sheet





sc1000 Display Module, Multi-Parameter Universal Controller

The Hach sc1000 Multi-parameter Universal Controller is a fully modular system consisting of a Display Module and one or more Probe Modules. The Display Module and Probe Module must be ordered separately.

  • Full featured controller with large color touch-screen display
  • Can accept up to 8 digital sensors (stand alone) or expanded to a 15 sensor network
  • Plug and play operation
  • Mix and match; compatible to all Hach digital sensors and analyzers
  • Flexible communication options - Modbus and Profibus DP
  • Digital reliability and integration
  • Expandable and upgradeable at any time

sc1000 Display Module, Multi-Parameter Universal Controller Data Sheet




PRO Series pH/ORP/Contacting Conductivity Transmitter

GLI's economical, menu-guided PRO-P3 Transmitter is easy to use, providing features normally found in more expensive units.
The NEMA 4X enclosure can be panel, wall, pipe, or integral sensor mounted. The interface is identical to GLI's 33-series analyzers.

pH/ORP:

  • Multiple Measurements (pH, ORP, temperature, analog output value)
  • Auto/Manual temperature compensation

Contacing Conductivity:

  • Multiple Measurements (µS/cm or mS/cm, resistivity , or TDS)
  • Ultrapure Water Capability
  • Unique DRY-CAL Calibration

General:

  • Versatile 2, 3, or 4-wire hookup capability
  • Universal mounting
  • Electromagnetic conformance
  • Multiple languages
  • Menu-guided
  • Passcode protected access
  • Isolated 4-20 mA output
  • Versatile sensor compatibility
  • Auto/Manual temperature compensation
  • Simple interactive diagnostics

Pro Series pH/ORP Data Sheet




53 Series Controller, NEMA 4x enclosure

All P53 Controllers have 4 electromechanical relays in a 1/2 DIN and hardware for panel, surface or pipe mounting. 2 year warranty.

  • Multiple language capability
  • Enhanced menu-guided operation
  • 1/2 DIN NEMA 4X enclosure
  • Universal mounting hardware

P53 pH/ORP Controller Data Sheet
C53 Conductivity Controller Data Sheet




33 Series panel mount case with NEMA 4X front Panel

GLI's 33 Series is a low-priced, full-featured analyzer, specifically designed for cost-conscious end users. The backlit LCD simultaneously displays the measured pH and process temperature.

  • Multiple language capability
  • Basic menu-guided operation
  • 1/4 DIN panel mount enclosure with NEMA 4x face

P33 pH/ORP Controller
C33 Conductivity Controller




si792 Transmitter, Class I Division 2 with standard HART communication

The Hach si792 2-wire transmitter also offers

  • Large, clear display
  • Icon-based messages for system status
  • Sensor diagnostics
  • System alarm indicated by red LED
  • HART communication for Class I, Division 2 or Class I, Division 1 applications

Si792P pH/ORP Transmitter Data Sheet
Si792C Conductivity Transmitter Data Sheet




APA6000 Process Analyser
  • Accuracy, quick response and reliable performance
  • Mechanically simple design for lowmaintenance operation
  • Easy to use with menu-driven interface
  • Stores, graphs and displays measurements for up to 30 days
  • Grab sample measurements can be taken without interrupting process flow
  • Analyzer will sequence up to three sample streams
  • Self-calibrating, selfcleaning and self-priming
  • Minimal reagent consumption
  • Self-diagnostics alert operator to alarm conditions in the instrument

APA6000 Process Analyser Data Sheet




CL17 Free / Total Residual Chlorine Analyzer
  • 0 to 5 mg/L range, dual, fully-adjustable set-point alarms
  • Uses the only EPA approved method for continuous chlorine monitoring
  • IP62 enclosure rating, suitable for indoor installation
  • Automatic, self-testing diagnostics
  • Minimal routine maintenance required
  • Colorimetric DPD chemistry - fast, reliable, economical
  • Unattended operation up to 30 days
  • Manual or automatic feed pump control

CL17 Free or Total Residual Chlorine Analyser Data Sheet





AMTAX(TM) sc Ammonia Analyzer, 0.05-20mg/l NH4-N, 230V, 5m Filter Probe sc

This Kit To Order Includes

  • 0.05 - 20 mg/L NH4-N, 230 VAC AMTAX sc Ammonia Analyzer
  • Filter Probe sc with 5 Meter Heated Hose
  • 3 Month supply of all necessary consumables at 5 minute cycle time
  • NOTE: This KTO must be connected to an sc1000 to form a complete loop

Wide measurement range for a variety of wastewater applications

  • Low detection limit of 0.05 mg/L
  • Fast 5 minute response time including sample preparation
  • Environmentally controlled for rugged, outdoor installations
  • Designed specifically for easy installation at the measurement point
  • Fully featured "Plug & Play" digital controller
  • Low Maintenance
    • The probe is equipped with a self-cleaning membrane
    • 3-Month supply of all consumables at the shortest cycle time (5 min)
    • Automatic cleaning and calibration every day
    • Comprehensive self-diagnostics
    • Easy access to reagents and wear parts

AMTAX sc Ammonia Analyser Data Sheet





PHOSPHAX(TM) sc Phosphate Analyzer, 0.05-15mg/l PO4-P, 115V, 5m Filter Probe sc

This Kit To Order Includes

  • 0.05 - 15 mg/L PO4-P, 115 VAC PHOSPHAX sc Ortho-Phosphate Analyzer
  • Filter Probe sc with 5 Meter Heated Hose
  • 3 Month supply of all necessary consumables at 5 minute cycle time
  • NOTE: This KTO must be connected to an sc1000 to form a complete loop

Wide measurement range for a variety of wastewater applications

  • Low detection limit of 0.05 mg/L
  • Fast 5 minute response time including sample preparation
  • Environmentally controlled for rugged, outdoor installations
  • Designed specifically for easy installation at the measurement point
  • Fully featured "Plug & Play" digital controller
  • Low Maintenance
    • The probe is equipped with a self-cleaning membrane
    • 3-Month supply of all consumables at the shortest cycle time (5 min)
    • Automatic cleaning and calibration every day
    • Conprehensive self-diagnostics
    • Easy access to reagents and wear parts

PHOSPHAX sc Phosphate Analyser Data Sheet




SP510 Hardness Analyzer
  • Trips Alarms Range Available
    • 0.3, 1, 2, 5, 10, 20, 50, 100mg/L
  • Immediately signal hardness breakthrough to activate regeneration
  • Makes your water softening system more efficient and less costly
  • Reliable, simple and accurate- with automated calibration
  • Continuous monitoring in "real time"

SP510 Hardness Analyser Data Sheet




HQ30d Single-Input Multi-Parameter Digital Meter

Plug and Play with IntelliCAL(TM) probes - pH, conductivity, LDO, and more*

  • Lighten your load with a single meter to measure either pH, Conductivity, or LDO interchangeably
  • Quick and easy swapping of parameter/probe without re-calibration
  • Password-protected data for accurate, tamper proof reporting
  • 500-point event log stores measurements, calibrations and check standards
  • This meter replaces the HQ10 LDO® meter.

HQ30d Digital Meter




HQ40d Dual-Input Multi-Parameter Digital Meter

The HQ40d Digital Multi-Parameter Meter offers true Plug and Play operation with IntelliCAL pH, conductivity, and dissolved oxygen (LDO) probes. Plug in any two IntelliCAL probes and get simultaneous measurement, simultaneous readout! "Smart" meters store probe serial numbers, calibration history, user ID, time, date and location of readings.

All data (up to 500 data points) can be accessed using a simple menu-driven interface with intuitive icons. Transfer GLP/ISO data effortlessly to a PC or USB flash stick.

HQ40d Digital Meter




Pocket Colorimeter II Analysis System

The new Pocket Colorimeter(TM) II Filter Photometer is a true go-anywhere instrument, lightweight and battery operated, suitable for extended field work or quick, on-the-spot process monitoring.

  • Waterproof, Lightweight, Economical
    The Pocket Colorimeter II Instrument really can be carried in your pocket! Weighing in at only .23 kg (8.1 oz), it even floats if accidentally dropped in water.
  • Accurate, Reproducible Measurements
    Despite accuracy comparable to a lab instrument, the low-cost Pocket Colorimeter II is simple enough to use that anyone can obtain reliable results.
  • Factory-Programmed
    Each Pocket Colorimeter II Instrument is pre-programmed for one of more than 35 parameters; many are based on EPA-approved methods. No manual calibration is ever required. Simply zero the instrument with a blank, insert the reacted sample, and read the result.
  • Improved Optics
    A long-lasting LED light source allows expanded ranges for ammonia, chlorine, chromium, copper, iron, and molybdenum, reducing the need for dilutions.

The Pocket Colorimeter II allows user calibrations, giving you the ability to create your own calibration curve, or to perform a standard adjust. We also manufacture wavelength-specific 'generic' instruments, allowing you to enter your own methods using from two up to ten standards.

Each Pocket Colorimeter II Instrument comes complete as a ready-to-use kit that includes a reagent set (pre-measured unit dose reagents), sturdy custom carrying case, and manual.

Pocket Colorimeter II Data Sheet




2100P Portable Turbidimeter
  • Turbidity range: 0 to 1000 NTU
  • Selectable signal averaging mode compensates for fluctuations in readings caused by movement of large particles in the light path
  • Pre-programmed calibration procedure, with microprocessor-controlled adjustment of calibration curve. No potentiometers to adjust
  • Electronic zeroing: compensates for electronic and optical offsets. No manual adjustments are required
  • Direct digital readout in NTU
  • Meets or exceeds USEPA method 180.1 criteria
  • Comes with six sample cells, 4 sealed vials of StablCal Primary Turbidity Standards (<0.1, 20, 100, and 800 NTU), Secondary Gelex Turbidity Standards, silicone oil and oiling cloth
  • Two-year warranty

2100P Portable Turbidimeter Data Sheet




DR 2800 Portable Spectrophotometer

The DR 2800 Portable Spectrophotometer adds new power to your work, in the lab or in the field

  • Touch screen display with intuitive user interface
  • USB ports for easy program updates and printer/accessory connections
  • Over 240 pre-installed analytical methods
  • Automatic test recognition when used with TNTplus barcoded vial tests
  • Small footprint
  • Open measurement
  • Runs on either line power or optional lithium-ion battery
  • Optional Pour-Thru Cell accessory for high volume analysis and trace level measurement

DR2800 Portable Spectrophotometer Data Sheet




LDO® Process Dissolved Oxygen Probe
  • Luminiscent Dissolved Oxygen (LDO)
    Range: 0.00 - 20.00 mg/L (0.1 - 20.0 ppm)
  • No calibration for one year
  • Reduced cleaning frequency and simple maintenance
  • 99% accuracy
  • No electrolyte solutions to poison or replenish
  • No membranes
  • Three year probe warranty
  • One year sensor warranty

LDO Process Dissolved Oxygen Probe Data Sheet




1720E Low Range Process Turbidimeter
Sensor Only

The 1720E Low Range Turbidimeter Sensor:

  • 0 to 100NTU
  • Meets and exceeds USEPA Method 180.1 for measuring turbidity for drinking water compliance
  • Plug and play connection
  • Sensitive to fine changes in low level turbidity with a built-in bubble removal system
  • Two year warranty

1720E Low Range Process Turbidimeter Data Sheet




9184sc Free Chlorine (TFC) Amperometric Sensor

The 9184sc Chlorine Sensor is an on-line, single-channel industrial sensor that measures free chlorine in drinking water treatment plants, distribution networks, and other applications that require monitoring of free chlorine at the ppb and ppm levels.

The 9184sc Chlorine Sensor also:

  • Expands the available technology of the digital sensor family
  • Offers a low minimum detection limit for efficient residual chlorine monitoring
  • Provides a wide continuous chlorine measurement Range: 0-20 mg/L
  • Allows for easy setup and maintenance
  • Is compatible with Hach Multi-Sensor, Multi-Parameter Digital Controllers
  • Is offered in models available to measure Hypochlorous Chlorine (HOCl) only (part number LXV430.99.00001), or Total Free Chlorine (TFC), when combined with a pH probe for accurate compensation of pH fluctuations (part number LXV432.99.00001)

9184sc Free Chlorine (TFC) Amperometric Sensor Data Sheet




NH4D sc Ammonium Sensor
  • Continuous trending of ammonium levels to control the nitrification process in municipal wastewater treatment plants with less than 30% industrial waste
  • Insitu sensor immerses directly in the process eliminating the need for sample preparation
  • Compact sensor cartridge simplifies maintenance
  • Exclusively from Hach, CARTRICAL(TM) technology reduces interferences providing greater accuracy
  • Economical continuous measurement
  • Optional automatic cleaning system

NH4Dsc Ammonium Sensor Data Sheet




NITRATAX(TM) Sensor
  • UV absorption method-proven, continuous, and precise
  • Eliminates reagents, sampling, and sample conditioning
  • Self-cleaning probe
  • Life-long factory calibration
  • Full-featured "plug and play" with sc100 Digital Controller

Nitratax Sensor Data Sheet



NO3D sc Nitrate Sensor
  • Continuous trending of nitrate levels to control the nutrient removal process in municipal wastewater treatment plants with less than 30% industrial waste
  • Insitu sensor immerses directly in the process eliminating the need for sample preparation
  • Compact sensor cartridge simplifies maintenance
  • Exclusively from Hach, CARTRICAL(TM) technology reduces interferences providing greater accuracy
  • Economical continuous measurement
  • Optional automatic cleaning system

NO3d sc Nitrate Sensor Data Sheet




Solitax Turbidity Sensor Only
  • Range: 0.0001 to 4000NTU, 0.0001mg/l to 50 / 500g/l
  • Materials: PVC or Stainless Steel
  • Optional Wiper for Automatic Cleaning (Time Based)

Solitax sc Turbidity Sensor Data Sheet




SONATAX sc SLUDGE LEVEL PROBE
  • Optimize sludge extraction, manage recirculation, warn of potential solids washouts, or process upset by continuously measuring the sludge blanket level
  • Reduced maintenance with innovative wiper design and quick LED system check
  • Superior accuracy and reliability with automatic frequency adjustment
  • Digitized probe eliminates interferences
  • Automatic temperature compensation and position sensor

Sonatax sc Sludge Level Probe Data Sheet




FilterTrak 660 sc Laser Nephelometer Network Add-on Sensor

FilterTrak 660 sc Laser Nephelometer

  • FilterTrak Laser Nephelometer offers the best resolution in the market, detects changes in turbidity as low as 0.0005 NTU
  • Meets all USEPA filtering monitoring requirements
  • Compatible with Hach Multi-Sensor, Multi-Parameter Digital Controllers, sensor can be used with Hach's new sc100 or sc1000 Digital Controllers

FilterTrak660sc Laser Nephelometer Sensor Data Sheet




6028 GLI Encapsulated LCP (Liquid Crystal Polymer) Differential pH Sensor with Internal Preamplifier and Glass Electrode, 5-Wire (10 ft. cable)

Convertible mounting style1 LCP (Liquid Crystal Polymer) Differential pH Sensor, with built-in preamplifier and glass electrode: 0-14 pH, 5-wire, 10 ft. cable.

Advantages of Hach LCP Differential pH sensors:

  • Double-junction salt bridge and pH 7 reference solution can easily be dismantled / replaced in the field, making the sensor very economical to maintain.
  • Chemically-resistant LCP Body material allows sensors to be used in aggressive process solutions, such as acids, bases, alcohols, hydrocarbons, aromatics, chlorinated hydrocarbons, esters, ketones, and most other chemicals.
  • LCP sensors are physically stable and will not expand or contract when subjected to the heating and cooling cycles of a process.
  • Integrated ground electrode eliminates measurement error due to ground loops that may exisit in the process.
  • Built-in preamp produces a strong signal, enabling you to locate the analyzer up to 914 m (3000 ft.) from the sensor.
  • 1 year warranty and 30 month pro-rated replacement.

6028 GLI Sensor Data Sheet




Surface Scatter 7 sc High Range Turbidimeter

The Surface Scatter 7 sc High Range Turbidimeter with sc100 controller offers superior performance features:

  • Virtually maintenance-free, optics never touch the sample
  • Wide turbidity measurement range; measures turbidity from 0 to 9999 NTU
  • Durable-manufactured with corrosion-resistant materials
  • Note: only one SS7 sc sensor can attach to one sc100 controller, if a second different sc sensor is required for this configuration please contact Pryde Measurement Pty Ltd

Surface Scatter 7 sc High Range Turbidimeter Data Sheet



TSS Portable Hand-held Turbidity, Suspended Solids, and Sludge Level System

Complete system including meter, probe, rechargeable batteries, charger for rechargeable batteries with four plug adapters, manual, quick start guide, and carrying case.

  • Three parameters in one instrument
  • Multiple calibration curves for convenience
  • Easy Sludge Blanket Levels
  • Air Bubble compensation for accuracy
  • Durable Materials for long life
  • Rechargeable battery power

TSS Portable Hand-Held Data Sheet



TSS HT sc, Suspended Solids High Temperature InSitu Sensor without a Wiper
  • Measures inline Turbidity and Suspended Solids in one instrument
  • Instrument software automatically compensates for air bubbles to prevent any interference in the Suspended Solids measurement
  • Connects directly to all Hach sc controllers for immediate use

TSS HT sc, Suspended Solids Sensor Data Sheet



UVAS Plus sc, UV Absorbance / %Transmittance Sensor
  • Measurement Path Length: 1, 2, 5 & 50mm
  • Measurement Range:
    • 0.01 to 60 m–1 at 50 mm
    • 0.1 to 600 m–1 at 5 mm
    • 0 to 1500 m–1 at 2 mm
    • 2 to 3000 m–1 at 1 mm
  • 10m Cable
  • User Maintenance: Typical 1 hour per month

UVAS Plus sc UV Absorbance / %Transmittance Sensor Data Sheet




FP360sc Oil in Water immersion probe
NOW AVAILABLE

Highly sensitive UV fluorometer detects smallest traces of oil in water.

Even the smallest oil traces impair water quality. The FP 360 sc monitors surface water, process water and industrial water continuously for traces of mineral oil contamination. The highly sensitive UV fluorometer is immersed directly in the medium.

  • Immersible probe: measures direct in the medium
  • Mineral oils in water - down to the trace range
  • Rugged probes, also available in titanium
  • Available with compressed air cleaning jet
  • Digital SC controller for up to 8 probes

FP360sc Oil in Water Immersion Probe Data Sheet



CLF10 / CLT10 sc Free / Total Chlorine Sensor, sc100 Controller and Stainless Steel Panel with pHD differential Sensor
NEW!

  • Compatible with Hach's "Plug and Play" Digital Controllers
  • EPA compliant according to Method 334.0
  • Exclusive Self Diagnostics

The CLT10 sc analyzer leverages Hach's exclusive self diagnostics to alert users whether the process has changed or the instrument needs servicing. Diagnostic features include the Cal Watch algorithm for warning of pH and chlorine calibration deviation and a non-contacting flow sensor for notification of insufficient sample flow.

No Reagent Replacement, No Waste Stream

Total chlorine measurement with an amperometric analyzer, such as the CLT10 sc, does not require reagents, eliminating the need for routine reagent replacement and waste stream management.

Real-time Process Control

The CLT10sc total chlorine analyzer allows for real-time control of disinfection processes by providing continuous readings that indicate when treatment conditions have changed.

CLF10 / CLT10 sc Total Chlorine Sensor, sc100 Controller and Stainless Steel Panel with pHD differential Sensor Data Sheet



Pryde Measurement Pty. Ltd.,
ACN 112 029 777
National Customer Service - Free Call: 1800-688-211

 

Brisbane
Forest Lake, QLD 4078
Industrial: 0425 800 681
Analytical: 0425 863 095
Fax: (03) 9567 0799
P.O. Box 77
Carole Park, QLD 4300
Melbourne
Unit 2, 615 Warrigal Rd,
Ashburton, VIC 3147
Phone: (03) 9567 0777
Fax: (03) 9567 0799
Locked Bag 600,
Ashburton, VIC 3147

Perth
Hillarys, WA 6923
Industrial: 0427 517 359
Fax: (03) 9567 0799
P.O Box 221
Hillarys, WA 6923

Sydney
Unit 6, 79 Williamson Road.
Ingleburn, NSW 2565
Phone: (02) 9618 5822
Fax: (02) 9618 5844
P.O.Box 327,
Ingleburn, NSW 2565