Pryde Measurement Pty Ltd - Measurement and Controls
RETURN TO HOME

Barometric Pressure
Humidity and Temperature
Barometric Pressure




Model 270
Weather Data Systems Laser Interferometers
Altimeter Setting Indicators Transfer Pressure Standard
Engine Test Cells

Full Scale Pressure Output: 5.0 VDC
Zero Pressure Output: 0 VDC
Accuracy: (RSS Method) ±0.05% Full Scale
Type of Pressure: Absolute,Gage,Barometric
Pressure Ranges: 0 to 10, 20, 50, 100 psia
0 to 5, 10, 20, 50, 100 psig
600 to 1100 hPa/mb
800 to 1100 hPa/mb
Thermal Effects Compensated Range °F (°C): 30 to 120 (-1 to 49)
%FS/100°F(100°C) max.zero:±0.2 (±0.36) hPa/mb
%FS/100°F(100°C)max.span: ±0.2 (±0.36) hPa/mb
%FS/100°F(100°C)max.zero: ±0.1 (±0.18) other ranges
%FS/100°F(100°C)max.span: ±0.1 (±0.18) other ranges

Media Non-condensing air or gas compatible with aluminum, alumina ceramics, gold, fluorocarbon elastomer sealant and Buna-N O-Ring

Model 270 Data Sheet...Click Here






Model 276
Weather and Environmental Data Logging
Clean Rooms Automotive Emissions
Altitude Applications

Full Scale Pressure Output 5.1 VDC, 4.5 for 5 VDC Excitation
Zero Pressure Output 0.1 VDC, 0.5 for 5 VDC Excitation
Accuracy: (RSS Method) ±0.25% Full Scale
Type of Pressure: Barometric, Absolute
Pressure Ranges
600 to 1100 hPa/mb
800 to 1100 hPa/mb
0 to 20 psia
Thermal Effects Compensated Range °F (°C): 30 to 130 (0 to 55)
%FS/100°F(100°C)max.zero: ±1.0 (±1.8)
%FS/100°F(100°C)max.span: ±1.0 (±1.8)
Media Non-condensing air or gas compatible with stainless steel, alumina ceramics, gold, and elastomer sealant.

Model 276 Data Sheet...Click Here



Model 278
Automatic weather stations
(AWS)
High accuracy barometric
pressure readings
Data loggers

Excitation 9.5 to 28VDC
Pressure Output 0 VDC ot 2.5VDC, 0 to 5 VDC
Type of Pressure: Barometric
Pressure Ranges
500 to 1100 hPa/mb, Accuracy +/- 0.6hPa/mb @ 20°C
600 to 1100 hPa/mb, Accuracy +/- 0.5hPa/mb @ 20°C
800 to 1100 hPa/mb, Accuracy +/- 0.3hPa/mb @ 20°C
Proof Pressure: 1500 hPa
Burst Pressure: 2000 hPa

Resolution: 0.01mb
Pressure fitting: 1/8" (ID dia.) Barbed fitting
Electrical Connection: 5-pin terminal block

Model 278 Data Sheet...Click Here





Model 370
Barometric Pressure Monitoring Altimeter Calibration
Pressure Switch Setting Laser Interferometers
Min/Max Tracking Hi/Lo Alarming
Pressure Transfer Standard

Accuracy: (RSS Method) ±0.02% Full Scale
Digital Output Bi-directional RS-232 Interface
Type of Pressure: Barometric, Absolute
Pressure Ranges 600 to 1100 hPa/mb
800 to 1100 hPa/mb
0 to 10, 20, 50, 100 psia
Thermal Effects Compensated Range °F (°C): 32 to 110 (0 to 45)
%FS/100°F(100°C)max.zero: ±0.2 (±0.4)
%FS/100°F(100°C)max.span: ±0.1 (±0.2)
Media Clean dry air or other gases (non-condensable)

Model 370 Data Sheet...Click Here







Model 470

Automatic Weather Reporting Systems Barometric Pressure Compensation for the Wavelength of Laser Beams
High Accuracy Altimeter Altimeter Calibration
Weather Data Buoy Pressure Transfer Standard

Accuracy: (RSS Method) ±0.02% Full Scale
Digital Output: Bi-directional RS-232 Interface
Type of Pressure: Barometric, Absolute
Pressure Ranges 600 to 1100 hPa/mb
800 to 1100 hPa/mb, 0 to 10, 20, 50, 100 psia
Thermal Effects Compensated Range °F (°C):
32 to 110 (0 to 45) %FS/100°F(100°C)
max.zero: ±0.2 (±0.4) %FS/100°F(100°C)
max.span: ±0.1 (±0.2)
Media Clean dry air or other gases (non-condensable)

Model 470 Data Sheet...Click Here


Humidity and Temperature









MP100H/400H

Typical applications include weather stations, airports, ice-warning systems, panorama TV systems, and outside condition monitoring for building management systems.
MP100/400H features the HygroClip S3 interchangeable sensor module for simplified field maintenance and calibration. The sensor module can be calibrated under laboratory or workshop conditions for best performance, then simply interchanged on site in minutes.

  • Technical Data: .
  • Operating range: 0...100%rh, -40...+85°C
  • Accuracy at 23°C: ± 1.5%rh, ± 0.3K
  • Long term stability: < 1%rh/year typical, 0.1°C/year
  • Analogue output signal: ROV = 10mV/%rm/°C
  • Digital output signal: DIO format
  • Adjustment: 4 points via PC (EEPROM)
  • Housing: IP65 ABS 100x15mm

MP100H/400H Data Sheet...Click Here






Hygroclip-SC3

Typical applications include weather stations and data acquisition systems. Available as an interchangeable HygroClip S3 module with a compatible 3m cable (MOK-03-XX), or with a fixed cable (HygroClip-S3C03).

  • Precise & stable %rh & temperature measurement
  • Economical price
  • Configured for outdoor measurements
  • Compact dimensions
  • Radiation shield available (AC1004)


Technical Data:
Humidity sensor: Hygromer C94
Temperature sensor: Pt100 1/3 DIN
Operating range: 0...100%rh, -40...+85°C
Accuracy at 23°C: ± 1.5%rh, ± 0.3K
Long term stability: < 1%rh/year typical, 0.1°C/year
Analogue output signal: ROV = 10mV/%rm/°C
Digital output signal: DIO format
Adjustment: 4 points via PC (EEPROM)
Housing: IP65 ABS 100x15mm

Hygroclip-SC3 Data Sheet...Click Here





RS12T / RS24T

The new Rs Ventilation sheild has been developed in close cooperation with the swiss national meteorological service. It is a highly advanced product, designed to minimise the influence of the thermal radiation on humidity and temperature measurements, whilst maximising protection from the very worst weather conditions, including horizontalyl driving wind and rain. The performance of the Rs sheild in combination with the latest Rotronic meteorological probes is such that in comparative tests, measurement perfomance was practical identical to reference chilled mirror condensation hygrometers which are used by many national meteorological Organisations.

Key Features:

  • East-to-Install protection sheild with buil-in ventillator
  • Special white paint minimises solar gain
  • Easy probe mounting
  • 12VDc or 24VDC supply for probe and fan.

RS12T / RS24T Data Sheet...Click Here





Accessories

A high quality range of installation accessories for ROTRONIC meteorological probes. VHTS2 radiation shield includes active ventilation to ensure the highest possible accuracy of measurement in any condition by circulating a steady flow of air over the sensors. The AC1003 radiation shield with passive ventilation protects the measurement probe from the effects of solar radiation and rainfall, and provides protection even with horizontal rain at up to 68km/h. Included with the AC1003, AC1012 is an extra protection tube for the connector and cable, to prevent water ingress even in the most severe conditions. The AC1004 shield offers passive protection and smaller dimensions to suit the HygroClip
probe options.

  • AC1003/AC1012 Passive radiation shield including cable protection tube suitable for MP100A/400A/100H/400H
  • VHTS ventilated shield for highest precision in all conditions. 24 V (24mA) or 12 V(60mA) power requirement
  • AC1004 Passive radiation shield for HygroClip S303 and MOK-03-XX with HygroClip-S

Accessories Data Sheet...Click Here






Pryde Measurement Pty. Ltd.,
ACN 004 560 374
National Customer Service - Free Call: 1800-688-211



Melbourne
Unit 2, 615 Warrigal Rd,
Ashburton, VIC 3147
Phone: (03) 9567 0777
Fax: (03) 9567 0799
Locked Bag 600,
Ashburton, VIC 3147
Brisbane
51 Yale Circuit
Forest Lake, QLD 4078
Mobile: 0425 863 095
Fax: (03) 9567 0799
Sydney
Unit 6, 79 Williamson Road.
Ingelburn, NSW 2565
Phone: (02) 9618 5822
Fax: (02) 9618 5844
P.O.Box 327,