SC5200

  • Consistent water quality
  • Uniform chemical dosing under varying conditions
  • Reduced chemical costs
  • Automatic operation of the treatment process

Specifications

  • Power: 115VAC, 50/60Hz(standard)
    Option: 240VAC, 50Hz (optional)
  • Output: 4-20mA Streaming current signal
    4-20mA Process signal (max. 500OHM load)
  • Meter Readout: Dual digital display: -100 to +100 Streaming currect units; and process set point.
  • Control Functions: Single loop proportional+intergral+derivative(PID) control; Continuous auto tune; Microprocessor based with self diagnostics; Automatic & manual mode selectable
  • Communications: RS-485 (optional)
  • Accuracy: 1% of full scale
  • Response Time: Less than 5 seconds
  • Gain Adjustment: Full range
  • Zero Adjustement: Full range
  • Signal Filter: Adjustable low pass
  • Sample Cell: Flow through, external type, Manual jet wash conn.(std)
    Automatic Jet Wash system(opt)
  • Sample Flow Rate: STD Probe: 2-4L/min(0.5-1 Gal/min) High Flow Probe: 4-20L/min (1-5Gal/min)
  • Sample Flow Sensor: Optional, Consult Product Manager
  • Sample Wetted Parts: PVC, Delrin, PTFE & Silver
  • Sample Connections: Barb Type 1/2" ID Tube(standard) Barb Type 1" ID tube (High Flow)
  • Alarms: Band type: deviation from set point
    Relays: SPDT,2amps at 115/230VAC
  • Operating Temp. 32°C to 120°F (0°C to 50°C)
  • Enclosure: NEMA 4X, 316SS
  • Weight: 24Lbs (10.91Kgs)

SC5200 Data Sheet









SC4200

  • Consistent water quality
  • Uniform chemical dosing under varying conditions
  • Reduced chemical costs
  • Reduced manual supervision and/or automatic operation of the treatment process

Specifications:

  • Power: 115VAC, 50/60Hz(standard)
    Option: 240VAC, 50Hz (optional)
  • Output: Two 4-20mA Streaming current signals. 1 fctory calibrated output; 1 customer calibrated output (max. 500OHM load each)
  • Meter Readout: Digital: -100 to +100 SC units
  • Operating Modes: Calibration and Run mode selectable
  • Accuracy: 1% of full scale
  • Response Time: Less than 5 seconds
  • Gain Adjustment: Full range continuous from 1-10 on front panel; additional internal adjust
  • Zero Adjustement: Full range
  • Signal Filter: Adjustable low pass
  • Sample Cell: Flow through, external type, Manual jet wash conn.(std)
    Automatic Jet Wash system(opt)
  • Sample Flow Rate: STD Probe: 2-4L/min(0.5-1 Gal/min) High Flow Probe: 4-20L/min (1-5Gal/min)
  • Sample Flow Sensor: Optional, Consult Product Manager
  • Sample Wetted Parts: PVC, Delrin, PTFE & Silver
  • Sample Connections: Barb Type 1/2" ID Tube(standard) Barb Type 1" ID tube (High Flow)
  • Alarms: High & Low adjustable Relays: SPST, 0.4amps at 115VAC
  • Operating Temp. 32°C to 120°F (0°C to 50°C)
  • Enclosure: NEMA 4X, 316SS
  • Weight: 24Lbs (10.91Kgs)
  • Remote Display Option: RC7200 Remote Controller Station (accepts 4-20mA signal from SC4200 via 2wire, twisted pair 22AWG)max 3000ft. seperation.

SC4200 Data Sheet






Pryde Measurement Pty. Ltd.,
ACN 112 029 777
National Customer Service - Free Call: 1800-688-211

 

Brisbane
Carole Park, QLD 4300
Phone: (03) 9567 0777
Melbourne
750 Queensberry Street,
North Melbourne, VIC 3051
Phone: (03) 9567 0777

Perth
Kwinana, WA 6966
Phone: 0427 517 359
P.O. Box 193
Kwinana, WA 6966

Sydney
Suite 2C, Centennial House
10 Ingleburn Road.
Ingleburn, NSW 2565
Phone: (02) 9618 5822
P.O.Box 327,
Ingleburn, NSW 2565