H2scan - HY-ALERTA® 600B Fixed Area Hydrogen Monitor
HY-ALERTA® 600B Fixed Area Hydrogen Monitor
Overview:
General Use Hydrogen Leak Detector
Detects 4000 ppm to 5% hydrogen concentration
No cross-sensitivity to other gases
Extended interface to several hundred feet
Applications
H2scan’s HY-ALERTA® 600B Fixed Area Hydrogen Monitor will provide hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit. They are designed for either ceiling or wall mount and have RS422 capability that extends the interface from the sensor to the controller to several hundred feet. H2scan’s hydrogen-specific sensor technology has no cross sensitivity to any other combustible gases, thus eliminating false positive alarms and increasing system reliability.
Battery Rooms
Control Rooms/Analyzer Buildings
Laboratories
Alternative Energy
Hydrogen Cooled Generators and Turbines
Industrial Gas Supply and Hydrogen Production
Furnaces and Manufacturing
Other Applications
Advantages
Highly reliable
Low life cycle cost
Easy to install and operate
Minimal maintenance required
No cross sensitivity to combustible gases
Not vulnerable to poisoning like other detectors
Wide hydrogen-specific detection range
Works in air, oxygen, or inert gas background
Non-consumable solid state technology
No cross sensitivity to combustible gases
Not vulnerable to poisoning like other detectors
Field-configurable settings
Will not saturate with exposure to hydrogen
Configuration Details
Hydrogen Sensitivity Range: 0.4% to 5.0% hydrogen by volume, (10% to 125% hydrogen lower flammable limit)
Accuracy: ±(0.03 x indication + 0.2) percent hydrogen by volume
Typical Response Time: T90 of 60 sec maximum
Ingress Protection: IP64 capable
Calibration Interval: 90 days
Product Life Expectancy: 10+ years
Operating Temperature Range: -20ºC to 40ºC
Storage Temperature Range: -40ºC to 80ºC
Operating Humidity: 0% tp 95% RH
Calibration Background Gas: Air
Input Voltage Range: 10VDC to 26VDC
Input Power: 15W max
Standard Analog Outputs:
0 VDC to 5 VDC or
4 mA to 20 mA
Custom ranges available
Serial Communication Options: RS-232 or RS-422
Relay Contacts:
Two programmable 30 VDC / 1 A SPDT relays with both normally open (N.O.) and normally closed (N.C.) contacts.
One programmable 30 VDC / 1 A SPDT relay with normally closed (N.C.) contacts.
Dimensions:
Total Length (600B): 8.2 in.
Mounting Bracket Length: 5.6 in.
Total Width: 4.4 in.
Mounting Bracket Width: 4.0 in.
Depth: 1.6 in.
Reliable Data for AI and Analytics
Proprietary self-monitoring technology continuously validates sensor performance, delivering clean, accurate data your AI and predictive maintenance initiatives demand. Unlike sensors that fail silently and corrupt your data record, H2scan sensors alert you immediately if performance degrades—ensuring every data point is reliable for both today’s monitoring needs and tomorrow’s analytics.
Certifications