top of page

Flow Measurement

SGM-Lektra Flow51

Compact flowmeter

Specification:

FLOW51 is a compact IP67 or IP68 ultrasonic flow transmitter, suitable for the installation in flood-prone wells. The measurement is based on the principle of the raising of the water level before restriction, which is used to calculate the value of instantaneous flow in relation of the type of the existing flume. FLOW51 can be calibrated via MODBUS RTU, Bluetooth or VLW60T if used with SGM LEKTRA Venturi flumes, Palmer Bowlus, Parshall flumes, Khafagi Venturi flumes and all the main types of weirs. In case of non-standard flumes the unit can be calibrated by following the linearization table present on the manual or by using a customized flow formula.

Compact system suitable to be installed upstream from hydraulic modelers (weirs, venturi, palmer bowlus)

Excellent price-performance ratio

Istantaneous and totalized flow measurement

Measure range 0.3รท6m

MODBUS RTU communication protocol; Bluetooth (opt.)

Remote control via Smartphone