Seli-Filliing Levels Type SMW 02
level-limit switch
Overview:
Features
Limit switch of the fill level for liquids DK>1
Two switching outputs for various media
e.g. Foam & Water / CIP & Product / etc .
Teaching input for teaching the media
Advanced settings, live process monitoring via PC
and programming adapter (Optional)
Welding socket system with modular
process connections and pressure screw connection
Defined position of the gland
Aseptic measuring point
Wetting parts made of peek
Partly moulded
EHEDG certified, FDA-conformal
Technical specifications
High-grade steel connecting head. Nr. 1.4305
Electr. Connection: M16 screwing or M12 plug 5-pole
Thread G 1/2” elastomer-free sealing system
Sensor heads made of Peek (HPC-Tip No.5)
Supply voltage 18...32 VDC
Output signal 2 x PNP (standard), NPN
or Push-Pull switchable NC / NO invertable
via PC
Permissible load, 0Ohm, 24VDC, 100mA
Response timet < 0,3s
ON / OFF delay 0..99.9 sec
Ambient temperature -10...+70°C
Medium temperature durable 0...+100°C
(with neck pipe durable up top 150°C)
CIP-/SIP cleaning 0... + 150°C (30 min)
Storage temperature -20...+70°C
Working pressure 10 bar max
(Higher pressures on request)
Protection IP68 / IP69K
EMC radiation / immunity, EN 6132623 (in closed container)
Torque max.: 20 Nm